About Us  Contact Us  Blog!  Home
CSE Industrial Electrical Distributors CSE Head Office
CSE Head Office :
01628 529448
CSE Southampton
CSE Southampton :
023 8063 3055
CSE Cables
CSE Cables :
01628 850024
ABB Drives Motor Control Gear Circuit Protection Switch Gear Special Offers Cable Industrial Controls
Danfoss Drives Cable Management Control Products Accessories Power Distribution Enclosures Buy On-Line
ABB ACS800 Industrial Drive
ACS800 Technical Spec
ABB ACH 550 Inverter drives
ACH550 rating / type / voltage
ACH550 ABB Press Releases
 ABB Motor Ratings
 ACH550 installation parts
 ACH550 Technical Spec
ABB ACS550 standard drives
ACS550 Ratings & Voltages
ACS550 Dimensions
ACS550 Options
ACS550 Plug in Options
ACS550 External Options
ACS550 Technical Spec
 ACS550 Technical Catalogue
ABB ACS350 drives
ACS350 Technical Spec
ACS350 Dimensions
ACS350 Interface Options
ACS350 Software Tools
 ACS350 Technical Catalogue
ABB ACS150 drives
ACS 150 Dimensions
ACS 150 Options
ACS150 Technical Spec
 ACS150 Technical Catalogue
ABB ACS50 drives
ACS50 Technical Spec
 ACS50 Technical Catalogue
General ABB drive information:
ABB Press Release
Climate change levy
Energy Saving
Single Phase Speed Controllers
ABB Variable Drive Case Studies / Applications
ABB HVAC Drive News
ABB HVAC Partners
ABB

Click for our HVAC drives on special offer

Click to send us a

Click for printer friendly version

Variable Flow Chilled Water System


Application Principle

Chilled water plants are generally one of two types: variable flow or constant flow. To reduce installation and operation cost, it is best to vary the chilled water flow throughout the building.  Doing this allows the chilled water temperature rise to remain constant during partial load conditions and chilled water flow to vary in proportion with the load.  By varying the flow, smaller pumps and piping can be used. The main circulating pump must be variable flow.  Multiple pumps can be stagged on, but variable speed AC drives are commonly used.

 
  Chilled water system with variable speed drives

Chilled water supply temperatures typically range from 5 to 10 degrees C higher.  This temperature increase is the key parameter for the variable flow system.  Once the temperature is selected, all equipment must be designed to operate within that range.  This means the chillers, air handling unit coils, and the control valves.

Detailed Description

This system for space cooling of several rooms with chilled water circulating through air terminal device (6) and thermostat valve (5) in each room.  The return water is circulated by a chiller water pump (1) through the chiller evaporator (3).  The water temperature is reduced in the evaporator by about 5 degrees C and it is supplied back to the rooms.  The variable water circulation is achieved by the AC drive (2) and the control parameter is the water pressure at the most distant room to keep the pressure high enough for the thermostat valves.  The pressure is measured by the transmitter (4).

Performance in Creating comfort zone

The use of variable speed AC drives improves the controllability of the whole chilled water system, causing good possibilities to maintain the Comfort Zone.

The use of variable speed drives usually increases the first cost of investment but through savings in electrical energy in motors alone the investment in VSD has pay back time between 0.2 - 3 years.

 
  A chiller unit on the roof of an industry building (Guangzhou, China)

In addition to savings in electrical energy, there are several important customer benefits speaking for VSD:

  • Fast control to maintain the comfort zone conditions
  • Accurate control to keep the desired air quality
  • Reduced pump and pipe size
  • Reduced consumption of electrical energy
  • Only one set of pumps is needed
 
     
   