VAV with Fan Tracking Positive Pressure


Application Principle

This Variable Air Volume system is a little simplified solution of the Variable Air Colum Systems with VSD Fan Control.  Instead of having constant static pressure or airflow control of the return air fan it is tracking the positive pressure by following the "master" supply fan speed.  The idea is to keep the return airflow equal to the supply airflow, which means that the fans should have equal capacity.  This method may be easier to be kept stable than the systems with static pressure controls.  This system used for multiple zone air conditioning usually has thermostat and damper controlled terminal units for each zone.

 
  Air conditioning system with variable speed drives

The system may be designed so that cooling of the rooms is obtained by outside air without operating the refrigeration plant.  Correct room temperature can be achieved by:

  • Air volume control
  • Bypass damper control
  • Control of heating or refrigeration capacity

Detailed Description

This variable air volume system brings outside air and return air to the Air Handling Unit (AHU) (3) where the incoming air (8) temperature and humidity can be controlled.  The main AHU components are supply air fan (2), heating coil (5), cooling coil (6), filter (7) and humidity control equipment (not drawn).  The three-way valves for heating and cooling are remotely operated by the control panel (11).  The temperature in the individual rooms is measured by thermostats (15), which directly control the dampers in the room terminal units.  The supply air fan is speed controlled by an AC drive (4) and it delivers the air to individual rooms throughout the building by supply air ducts.  The AC drive controls the air volume by keeping the pressure constant.  The pressure is measured by the sensor (13).  The return air fan (1) delivers the exhaust air (9) out of the building or part of the air (10) is returned back to the AHU.  The return fan is controlled by an AC drive (14), which is following the speed of the supply fan.

Performance in Creating comfort zone

The use of variable speed AC drives improves the controllability of the whole heating, cooling and air conditioning system, enabling good possibilities to maintain the Comfort Zone.  The use of variable speed drives usually increases the first cost of investment but through savings in electrical energy in motors along the investment in VSD has pay-back time between 0.2-3 years.

In addition to savings in electrical energy, there are several important customer benefits speaking for VSD:

 
  Air conditioning is an important system in industrial buildings (Guangzhou, China)
  • Fast control to maintain the comfort zone conditions
  • Accurate control to keep the desired air quality
  • Reduced consumption of heating and cooling energy
  • Reduced consumption of electrical energy
  • Simple to keep the noise level down
 