ABB Drives Motor Control Gear Circuit Protection Switch Gear Special Offers Cable Industrial Controls
Danfoss Drives Cable Management Control Products Accessories Power Distribution Enclosures Buy On-Line
Belden Coaxial
Belden Industrial Ethernet
Belden Twinax Blue Hose
Belden EIA Industrial RS 485
Belden Industrial Twinax Twinaxial
Shielded Twisted Pair cables
Belden EIA data cables
Belden Industrial Twinax + Datatray
Belden DataBus, Fieldbus or Profibus cables
Belden DeviceBus Phoenix
Belden DeviceBus Honeywell
Belden cable cross reference
Belden Cable jacket properties
Belden jackets & insulations overview
Belden shielding overview
Belden metal clad cable
Belden metal clad cable spec's
Belden 8471 Paired Cable

Click to send us a

 

Belden DeviceBus ® for ODVA DeviceNet TM

Belden Industrial Data Solutions ®- Industrial Data - DeviceBus ® for ODVA DeviceNet TM

 

CSE holds supplies a wide range of Belden cables - Contact Corrina, our cable expert at

Belden 3084A

  • 300V Class 2 Thin
  • 22 and 24 AWG Stranded Tinned Copper
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain Wire
  • PVC Insulation (Power)
  • FPE Insulation (data)
  • Lt Gray sunlight / oil resistant PVC jacket
  • Thin 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
  • Nominal OD - 0.28", 7.11mm
 

Belden 3084a Cable - Devicebus
Belden 3084A Devicebus (r) Thin Cable

Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 26.0 49.0 100.0
Standard unit weight (kgs) 11.8 22.3 45.5

 

Belden 3082A

  • 300V Class 2 thick
  • 15 and 18 AWG stranded tinned copper
  • 100% individually foil shielded + overall 65% TC braid
  • Drain Wire
 

Belden 3082a
Belden 3082A Deveicebus (r) Thick Cable

  • PVC Insulation (power)
  • FPE insulation (data)
  • Lt grey sunlight / oil resistant PVC jacket
  • Thick 75oC
  • Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (19 x 28) 3.6 Ω / M', 11.8 Ω / km, 18 AWG TC (19 x 30) 6.9  Ω / M', 22.6 Ω / km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.9 Ω /km
  • Nominal core OD - 0.460", 11.68mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 64.0 128.0 260.0
Standard unit weight (kgs) 29.1 58.2 118.2


Belden 3082F

  • 300V Class 2 thick
  • 15 and 18 AWG stranded tinned copper
  • 100% individually foil shielded + overall 65% TC braid
  • Drain Wire
  • PVC Insulation (power)
  • FPE insulation (data)
  • Lt grey sunlight / oil resistant PVC jacket
  • Thick 75oC
  • Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (65 x 33) 3.6 Ω / M', 11.8 Ω / km, 18 AWG TC (65 x 36) 6.9 Ω / M', 22.6 Ω / km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.9 Ω /km
  • Nominal OD - 0.460", 11.68mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 72.0 140.0 284.0
Standard unit weight (kgs) 32.7 63.6 129.1


Belden 3082K

  • Flat, 16 AWG stranded (19 x 29) tinned copper
  • Unshielded
  • PVC insulation (power)
  • FPE insulation (data)
  • Lt. grey sunlight-resistant PVC jacket
  • Class 2 300V 75oC
  • Conductor (stranding) Diameter Nom. DCR - 16 AWG TC (19 x 29) 4.9 Ω / M', 16.1 Ω / km
  • Shielding materials Nom. DCR - unshielded
  • Nominal OD - 0.760 x 0.210", 10.92 x 5.33mm
Standard Length (ft) 246 656 1378
Standard Length (m) 75.0 200.0 420.0
Standard unit weight (lbs) 30.8 78.7 165.4
Standard unit weight (kgs) 14.0 35.8 75.2


Belden 3082KP

  • PVC insulation
  • Black sunlight-resistant PVC jacket
  • Conductor (stranding) Diameter Nom. DCR - 16 AWG TC (19 x 29) 4.9 Ω / M', 16.1 Ω / km
  • Shielding materials Nom. DCR - unshielded
  • Nominal OD - 0.760 x 0.210", 10.92 x 5.33mm
Standard Length (ft) 246 656 1378
Standard Length (m) 75.0 200.0 420.0
Standard unit weight (lbs) 32.0 81.3 170.9
Standard unit weight (kgs) 14.5 37.0 77.7


Belden 3083A

  • PVC Insulation (power)
  • FPE insulation (data)
  • Yellow CPE jacket
  • Thick 80oC
  • Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (19 x 28) 3.6 Ω / M', 11.8 Ω / km; 18 AWG TC (19 x 30) 6.9 Ω / M', 11.8 Ω / km
  • Shielding materials Nom. DCR - unshielded
  • Nominal OD - 0.475", 12.07mm
Standard Length (ft) 1000 2000
Standard Length (m) 304.8 609.6
Standard unit weight (lbs) 133.0 270.0
Standard unit weight (kgs) 60.5 122.7


Belden 3084F

  • 300V Class 2 Thin
  • 22 and 24 AWG Stranded Tinned Copper
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain Wire
  • PVC Insulation (Power)
  • FPE Insulation (data)
  • Lt Gray sunlight / oil resistant PVC jacket
  • High flex Thin 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
  • Nominal OD - 0.275", 6.99mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 23.5 45.0 90.0
Standard unit weight (kgs) 10.7 20.5 40.9


 

Belden 3085A

  • 300V Class 2 Thin
  • 22 and 24 AWG Stranded Tinned Copper
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain Wire
  • PVC Insulation (power), FPE insulation (Data)
  • Yellow CPE jacket
  • Thin 80oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
  • Nominal OD - 0.280", 7.11mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 25.0 47.0 96.0
Standard unit weight (kgs) 11.4 21.4 43.6


Belden 7895A

  • 300V Class 2 ODVA Cable III
  • 20 and 18 AWG stranded TC
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain Wire
  • PVC Insulation (power), FPE insulation (Data)
  • Lt. grey sunlight / oil resistant PVC jacket
  • Mid 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 20 AWG TC (19 x 32) 10.9 Ω/ M', 35.8 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
  • Nominal OD - 0.378", 9.60mm
Standard Length (ft) 500 1000
Standard Length (m) 152.4 304.8
Standard unit weight (lbs) 42.0 83.0
Standard unit weight (kgs) 19.1 37.7


Belden 7896A

  • 600V Class 1 ODVA Cable V
  • 16 and 18 AWG Stranded tinned copper
  • 100% individually foil shielded + overall 65% TC Braid
  • PVC / nylon insulation (power)
  • F-R polypropylene insulation (data)
  • Open wiring 600V 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 16 AWG TC (19 x 29) 4.9 Ω/ M', 16.1 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.7 Ω /km
  • Nominal OD - 0.502", 12.75mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 70.0 136.0 276.0
Standard unit weight (kgs) 31.8 64.8 125.5


Belden 7897A

  • 600V Class 1 Thick
  • 15 and 18 AWG Stranded tinned copper
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain wire
  • PVC / Nylon insulation (power); FEP Insulation (data)
  • Lt. grey sunlight / oil resistant PVC jacket
  • High velocity thick 600V 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 15 AWG TC (19 x 28) 3.6 Ω/ M', 11.8 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.7 Ω /km
  • Nominal OD - 0.440", 11.18mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 63.5 124.0 250.0
Standard unit weight (kgs) 28.9 56.4 113.6


Belden 7900A

  • 600V Class 1 ODVA Cable IV
  • 16 and 18 AWG Stranded tinned copper
  • Unshielded
  • PVC / Nylon insulation (power); FEP Insulation (data)
  • Lt. grey sunlight / oil resistant PVC jacket
  • High velocity thick 600V 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 16 AWG TC (19 x 29) 4.9 Ω/ M', 16.1 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
  • Shielding materials Nom. DCR - Unshielded
  • Nominal OD - 0.430", 10.92mm
Standard Length (ft) 500 1000
Standard Length (m) 152.4 304.8
Standard unit weight (lbs) 45.0 92.0
Standard unit weight (kgs) 20.5 41.8

 

 

     
Electrical Accessories - Stego Thermostats, fans and filter, duracell batteries and stego heaters  
CSE Industrial Electrical Distributors
Email :
- UK enquiries- 01628 850024
Tel : International enquiries +44 (0)1628 850024, Fax -
+44 (0)1628 648068