Click to send us a

|
|
 |
Belden DeviceBus ® for ODVA
DeviceNet TM
Belden Industrial Data Solutions ®-
Industrial Data - DeviceBus ®
for ODVA DeviceNet TM |
|
CSE holds supplies a wide range of Belden cables - Contact Corrina, our cable expert at
|
|
|
- 300V Class 2 Thin
- 22 and 24 AWG Stranded Tinned Copper
- 100% individually foil shielded + overall 65% TC Braid
- Drain Wire
- PVC Insulation (Power)
- FPE Insulation (data)
- Lt Gray sunlight / oil resistant PVC jacket
- Thin 75oC
-
Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154
x 44) 17.5 Ω/ M',
57.4
Ω /km
-
Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105
x 44) 28.0 Ω/ M',
91.9
Ω /km
-
Shielding materials Nom. DCR - 100% individual foil + overall
65% TC braid 3.2 Ω/ M',
10.5
Ω /km
-
Nominal OD - 0.28", 7.11mm
|
|

Belden 3084A Devicebus (r) Thin Cable |
| Standard Length (ft) |
500 |
1000 |
2000 |
| Standard Length (m) |
152.4 |
304.8 |
609.6 |
| Standard unit weight (lbs) |
26.0 |
49.0 |
100.0 |
| Standard unit weight (kgs) |
11.8 |
22.3 |
45.5 |
-
300V Class 2 thick
-
15 and 18 AWG stranded tinned copper
-
100% individually foil shielded + overall 65% TC braid
-
Drain Wire
|
|

Belden 3082A Deveicebus (r) Thick Cable |
-
PVC Insulation (power)
-
FPE insulation (data)
-
Lt grey sunlight / oil resistant PVC jacket
-
Thick 75oC
-
Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (19 x 28)
3.6 Ω / M', 11.8
Ω / km, 18 AWG TC (19 x 30) 6.9 Ω
/ M', 22.6
Ω / km
-
Shielding materials Nom. DCR - 100% individual foil + overall
65% TC braid 1.8 Ω/ M', 5.9
Ω /km
-
Nominal core OD - 0.460", 11.68mm
| Standard Length (ft) |
500 |
1000 |
2000 |
| Standard Length (m) |
152.4 |
304.8 |
609.6 |
| Standard unit weight (lbs) |
64.0 |
128.0 |
260.0 |
| Standard unit weight (kgs) |
29.1 |
58.2 |
118.2 |
-
300V Class 2 thick
-
15 and 18 AWG stranded tinned copper
-
100% individually foil shielded + overall 65% TC braid
-
Drain Wire
-
PVC Insulation (power)
-
FPE insulation (data)
-
Lt grey sunlight / oil resistant PVC jacket
-
Thick 75oC
-
Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (65 x 33)
3.6 Ω / M',
11.8
Ω / km, 18 AWG TC (65 x 36) 6.9 Ω / M',
22.6
Ω / km
-
Shielding materials Nom. DCR - 100% individual foil + overall
65% TC braid 1.8 Ω/ M',
5.9
Ω /km
-
Nominal OD - 0.460", 11.68mm
| Standard Length (ft) |
500 |
1000 |
2000 |
| Standard Length (m) |
152.4 |
304.8 |
609.6 |
| Standard unit weight (lbs) |
72.0 |
140.0 |
284.0 |
| Standard unit weight (kgs) |
32.7 |
63.6 |
129.1 |
-
Flat, 16 AWG stranded (19 x 29) tinned copper
-
Unshielded
-
PVC insulation (power)
-
FPE insulation (data)
-
Lt. grey sunlight-resistant PVC jacket
-
Class 2 300V 75oC
-
Conductor (stranding) Diameter Nom. DCR - 16 AWG TC (19 x 29)
4.9 Ω / M',
16.1
Ω / km
-
Shielding materials Nom. DCR - unshielded
-
Nominal OD - 0.760 x 0.210", 10.92 x 5.33mm
| Standard Length (ft) |
246 |
656 |
1378 |
| Standard Length (m) |
75.0 |
200.0 |
420.0 |
| Standard unit weight (lbs) |
30.8 |
78.7 |
165.4 |
| Standard unit weight (kgs) |
14.0 |
35.8 |
75.2 |
-
PVC insulation
- Black sunlight-resistant PVC jacket
-
Conductor (stranding) Diameter Nom. DCR - 16 AWG TC (19 x 29)
4.9 Ω / M',
16.1
Ω / km
-
Shielding materials Nom. DCR - unshielded
-
Nominal OD - 0.760 x 0.210", 10.92 x 5.33mm
| Standard Length (ft) |
246 |
656 |
1378 |
| Standard Length (m) |
75.0 |
200.0 |
420.0 |
| Standard unit weight (lbs) |
32.0 |
81.3 |
170.9 |
| Standard unit weight (kgs) |
14.5 |
37.0 |
77.7 |
- PVC Insulation (power)
- FPE insulation (data)
- Yellow CPE jacket
- Thick 80oC
-
Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (19 x 28)
3.6 Ω / M',
11.8
Ω / km; 18 AWG TC (19 x 30) 6.9 Ω / M',
11.8
Ω / km
-
Shielding materials Nom. DCR - unshielded
-
Nominal OD - 0.475", 12.07mm
| Standard Length (ft) |
1000 |
2000 |
| Standard Length (m) |
304.8 |
609.6 |
| Standard unit weight (lbs) |
133.0 |
270.0 |
| Standard unit weight (kgs) |
60.5 |
122.7 |
- 300V Class 2 Thin
- 22 and 24 AWG Stranded Tinned Copper
- 100% individually foil shielded + overall 65% TC Braid
- Drain Wire
- PVC Insulation (Power)
- FPE Insulation (data)
- Lt Gray sunlight / oil resistant PVC jacket
- High flex Thin 75oC
-
Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154
x 44) 17.5 Ω/ M',
57.4
Ω /km
-
Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105
x 44) 28.0 Ω/ M',
91.9
Ω /km
-
Shielding materials Nom. DCR - 100% individual foil + overall
65% TC braid 3.2 Ω/ M',
10.5
Ω /km
-
Nominal OD - 0.275", 6.99mm
| Standard Length (ft) |
500 |
1000 |
2000 |
| Standard Length (m) |
152.4 |
304.8 |
609.6 |
| Standard unit weight (lbs) |
23.5 |
45.0 |
90.0 |
| Standard unit weight (kgs) |
10.7 |
20.5 |
40.9 |
- 300V Class 2 Thin
- 22 and 24 AWG Stranded Tinned Copper
- 100% individually foil shielded + overall 65% TC Braid
- Drain Wire
- PVC Insulation (power), FPE insulation (Data)
- Yellow CPE jacket
- Thin 80oC
-
Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154
x 44) 17.5 Ω/ M',
57.4
Ω /km
-
Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105
x 44) 28.0 Ω/ M',
91.9
Ω /km
-
Shielding materials Nom. DCR - 100% individual foil + overall
65% TC braid 3.2 Ω/ M',
10.5
Ω /km
-
Nominal OD - 0.280", 7.11mm
| Standard Length (ft) |
500 |
1000 |
2000 |
| Standard Length (m) |
152.4 |
304.8 |
609.6 |
| Standard unit weight (lbs) |
25.0 |
47.0 |
96.0 |
| Standard unit weight (kgs) |
11.4 |
21.4 |
43.6 |
- 300V Class 2 ODVA Cable III
- 20 and 18 AWG stranded TC
- 100% individually foil shielded + overall 65% TC Braid
- Drain Wire
- PVC Insulation (power), FPE insulation (Data)
- Lt. grey sunlight / oil resistant PVC jacket
- Mid 75oC
-
Conductor (stranding) Diameter Nom. DCR - (2) 20 AWG TC (19
x 32) 10.9 Ω/ M',
35.8
Ω /km
-
Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x
30) 6.9 Ω/ M',
22.6
Ω /km
-
Shielding materials Nom. DCR - 100% individual foil + overall
65% TC braid 3.2 Ω/ M',
10.5
Ω /km
-
Nominal OD - 0.378", 9.60mm
| Standard Length (ft) |
500 |
1000 |
| Standard Length (m) |
152.4 |
304.8 |
| Standard unit weight (lbs) |
42.0 |
83.0 |
| Standard unit weight (kgs) |
19.1 |
37.7 |
- 600V Class 1 ODVA Cable V
- 16 and 18 AWG Stranded tinned copper
- 100% individually foil shielded + overall 65% TC Braid
- PVC / nylon insulation (power)
- F-R polypropylene insulation (data)
- Open wiring 600V 75oC
-
Conductor (stranding) Diameter Nom. DCR - (2) 16 AWG TC (19
x 29) 4.9 Ω/ M',
16.1
Ω /km
-
Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x
30) 6.9 Ω/ M',
22.6
Ω /km
-
Shielding materials Nom. DCR - 100% individual foil + overall
65% TC braid 1.8 Ω/ M', 5.7
Ω /km
-
Nominal OD - 0.502", 12.75mm
| Standard Length (ft) |
500 |
1000 |
2000 |
| Standard Length (m) |
152.4 |
304.8 |
609.6 |
| Standard unit weight (lbs) |
70.0 |
136.0 |
276.0 |
| Standard unit weight (kgs) |
31.8 |
64.8 |
125.5 |
- 600V Class 1 Thick
- 15 and 18 AWG Stranded tinned copper
- 100% individually foil shielded + overall 65% TC Braid
- Drain wire
- PVC / Nylon insulation (power); FEP Insulation (data)
- Lt. grey sunlight / oil resistant PVC jacket
- High velocity thick 600V 75oC
-
Conductor (stranding) Diameter Nom. DCR - (2) 15 AWG TC (19
x 28) 3.6 Ω/ M',
11.8
Ω /km
-
Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x
30) 6.9 Ω/ M',
22.6
Ω /km
-
Shielding materials Nom. DCR - 100% individual foil + overall
65% TC braid 1.8 Ω/ M', 5.7
Ω /km
-
Nominal OD - 0.440", 11.18mm
| Standard Length (ft) |
500 |
1000 |
2000 |
| Standard Length (m) |
152.4 |
304.8 |
609.6 |
| Standard unit weight (lbs) |
63.5 |
124.0 |
250.0 |
| Standard unit weight (kgs) |
28.9 |
56.4 |
113.6 |
- 600V Class 1 ODVA Cable IV
- 16 and 18 AWG Stranded tinned copper
- Unshielded
- PVC / Nylon insulation (power); FEP Insulation (data)
- Lt. grey sunlight / oil resistant PVC jacket
- High velocity thick 600V 75oC
-
Conductor (stranding) Diameter Nom. DCR - (2) 16 AWG TC (19
x 29) 4.9 Ω/ M',
16.1
Ω /km
-
Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x
30) 6.9 Ω/ M',
22.6
Ω /km
-
Shielding materials Nom. DCR - Unshielded
-
Nominal OD - 0.430", 10.92mm
| Standard Length (ft) |
500 |
1000 |
| Standard Length (m) |
152.4 |
304.8 |
| Standard unit weight (lbs) |
45.0 |
92.0 |
| Standard unit weight (kgs) |
20.5 |
41.8 |
|