About Us  Contact Us  Blog!  Home
CSE Industrial Electrical Distributors CSE Head Office
CSE Head Office :
01628 529448
CSE Southampton
CSE Southampton :
023 8063 3055
CSE Cables
CSE Cables :
01628 850024
ABB Drives Motor Control Gear Circuit Protection Switch Gear Special Offers Cable Industrial Controls
Danfoss Drives Cable Management Control Products Accessories Power Distribution Enclosures Buy On-Line
Belden Coaxial
Belden Industrial Ethernet
Belden Twinax Blue Hose
Belden EIA Industrial RS 485
Belden Industrial Twinax Twinaxial
Shielded Twisted Pair cables
Belden EIA data cables
Belden Industrial Twinax + Datatray
Belden DataBus, Fieldbus or Profibus cables
Belden DeviceBus Phoenix
Belden DeviceBus Honeywell
Belden cable cross reference
Belden Cable jacket properties
Belden jackets & insulations overview
Belden shielding overview
Belden metal clad cable
Belden metal clad cable spec's
Belden 8471 Paired Cable

Click to send us a

 

Belden Industrial Twin Cables

Belden industrial data solutions - industrial twinax, twinaxial cables.  CSE supplies a range of the Belden coaxial cables.

 

CSE holds supplies a wide range of Belden cables - Contact Corrina, our cable expert at

Belden 9841

  • 24 AWG stranded (7 x 32), tinned copper
  • Twisted pairs
  • Overall 100% Beldfoil® + 90% TC braid shield
  • 24AWG stranded TC drain wire
  • Polyethylene insulation, chrome PVC jacket
  • UL AWM Style 2919 (30V 80oC)
  • Conductor Nom. DCR - 24.0 Ω/ M', 78.7 Ω /km
  • Shield Nom. DCR - 3.4 Ω/ M', 11.0 Ω /km
  • Nominal OD - 0.232", 5.89mm
Standard Length (ft) 100 500 1000
Standard Length (m) 30.5 152.4 304.8
Standard unit weight (lbs) 4.8 20.0 40.0
Standard unit weight (kgs) 2.2 9.1 18.2

 

Belden 9841NH

  • 24 AWG stranded (7 x 32), tinned copper
  • Twisted pairs
  • Overall 100% Beldfoil® + 90% TC braid shield
  • 24AWG stranded TC drain wire
  • Polyethylene insulation, chrome low smoke, zero halogen jacket
  • 80oC
  • Conductor Nom. DCR - 24.0 Ω/ M', 78.7 Ω /km
  • Conductor Shield  DCR - 3.4 Ω/ M', 11.0 Ω /km
  • Nominal OD - 0.232", 5.90mm
Standard Length (ft) 1000 1640 3280
Standard Length (m) 305 500 1000
Standard unit weight (lbs) 38.1 65.0 124.7
Standard unit weight (kgs) 17.3 29.5 56.6

 

Belden 9841LS

  • 24 AWG stranded (7 x 32), tinned copper
  • Twisted pairs
  • Overall 100% Beldfoil® + 90% TC braid shield
  • 24AWG stranded TC drain wire
  • Polyethylene insulation, black low smoke, zero halogen jacket, steel wire armour
  • 80oC
  • Conductor Nom. DCR - 24.0 Ω/ M', 78.7 Ω /km
  • Conductor Shield  DCR - 3.4 Ω/ M', 11.0 Ω /km
  • Nominal OD - Under armour 0.232", 5.90mm; Over Armour 0.406", 10.30mm
Standard Length (ft) 1000 1640 3280
Standard Length (m) 305 500 1000
Standard unit weight (lbs) 38.1 65.0 124.7
Standard unit weight (kgs) 17.3 29.5 56.6


Belden 9842

  • 24 AWG stranded (7 x 32), tinned copper

  • Twisted pairs

  • Overall 100% Beldfoil® + 90% TC braid shield

  • 24AWG stranded TC drain wire

  • Polyethylene insulation, chrome PVC jacket

  • UL AWM Style 2919 (30V 80oC)

  • Nom. DCR - Conductor 24.0 Ω/ M', 78.7 Ω /km; Shield 2.2 Ω/ M', 7.2 Ω /km

  • Nominal OD - 0.340", 8.64mm

Standard Length (ft) 100 500 1000
Standard Length (m) 30.5 152.4 304.8
Standard unit weight (lbs) 5.8 29.5 57.0
Standard unit weight (kgs) 2.6 13.4 25.9


Belden 9842LS

  • 24 AWG stranded (7 x 32), tinned copper
  • Twisted pairs
  • Overall 100% Beldfoil® + 90% TC braid shield
  • 24AWG stranded TC drain wire
  • Polyethylene insulation, black low smoke, zero halogen jacket
  • Steel wire armour
  • 80oC
  • Nom. DCR - Conductor 24.0 Ω/ M', 78.7 Ω /km; Shield 2.2 Ω/ M', 7.2 Ω /km
  • Nominal OD - Under armour - 0.341", 8.65mm; Over armour - 0.561", 13.10mm
Standard Length (ft) 1000 1640 3280
Standard Length (m) 305 500 1000
Standard unit weight (lbs) 195.4 334.8 647.6
Standard unit weight (kgs) 88.7 152.0 294.0


Belden 9842NH

  • 24 AWG stranded (7 x 32), tinned copper
  • Twisted pairs
  • Overall 100% Beldfoil® + 90% TC braid shield
  • 24AWG stranded TC drain wire
  • Polyethylene insulation, chrome low smoke, zero halogen jacket
  • 80oC
  • Nom. DCR - Conductor 24.0 Ω/ M', 78.7 Ω /km; Shield 2.2 Ω/ M', 7.2 Ω /km
  • Nominal OD - 0.341", 8.65mm
Standard Length (ft) 1000 1640 3280
Standard Length (m) 305 500 1000
Standard unit weight (lbs) 64.3 102.6 196.3
Standard unit weight (kgs) 29.2 46.6 89.1
     
Electrical Accessories - Stego Thermostats, fans and filter, duracell batteries and stego heaters  
CSE Industrial Electrical Distributors
Email :
- UK enquiries- 01628 850024
Tel : International enquiries +44 (0)1628 850024, Fax -
+44 (0)1628 648068