Belden EIA Industrial RS 485 Cables
Belden industrial data solutions - EIA industrial RS 485 PLTC / CM, HART, CAN cable.
- 22 AWG stranded (7 x 30) tinned copper, twisted pairs, overall 100% Beldfoil® shield + 90% TC braid, 22 AWG stranded TC drain wire
- Datalene® insulation, black UV resistant PVC jacket (CPE jacket optional)
- Oil res II 300 V
- Conductor Nominal DCR conductor - 14.7Ω/M', 48.2Ω/km
- Conductor Nominal DCR shield - 2.9Ω/M', 9.5Ω/km
- Nominal OD - 0.286 inch / 7.26mm
| Standard Length (ft) |
500 |
1000 |
5000 |
| Standard Length (m) |
152.4 |
304.8 |
1523.9 |
| Standard unit weight (lbs) |
25.0 |
50.0 |
255.0 |
| Standard unit weight (kgs) |
11.4 |
22.7 |
115.9 |
- 22 AWG stranded (7 x 30) tinned copper, twisted pairs, overall 100% Beldfoil® shield + 90% TC braid, 22 AWG stranded TC drain wire
- Datalene® insulation, black UV resistant PVC jacket (CPE jacket optional)
- Oil res II 300 V
- Conductor Nominal DCR conductor - 14.7Ω/M', 48.2Ω/km
- Conductor Nominal DCR shield - 2.8Ω/M', 9.2Ω/km
- Nominal OD - 0.302 inch / 7.67mm
| Standard Length (ft) |
500 |
1000 |
5000 |
| Standard Length (m) |
152.4 |
304.8 |
1523.9 |
| Standard unit weight (lbs) |
27.0 |
51.0 |
260.0 |
| Standard unit weight (kgs) |
12.3 |
23.2 |
118.2 |
- 22 AWG stranded (7 x 30) tinned copper, twisted pairs, overall 100% Beldfoil® shield + 90% TC braid, 22 AWG stranded TC drain wire
- Datalene® insulation, black UV resistant PVC jacket (CPE jacket optional)
- Oil res II 300 V
- Conductor Nominal DCR conductor - 14.7Ω/M', 48.2Ω/km
- Conductor Nominal DCR shield - 1.4Ω/M', 4.6Ω/km
- Nominal OD - 0.356 inch / 9.04mm
| Standard Length (ft) |
1000 |
4000 |
5000 |
| Standard Length (m) |
304.8 |
1219.2 |
1523.9 |
| Standard unit weight (lbs) |
73.0 |
300.0 |
385.0 |
| Standard unit weight (kgs) |
33.2 |
136.4 |
175.0 |
- 22 AWG stranded (7 x 30) tinned copper, twisted pairs, overall 100% Beldfoil® shield + 90% TC braid, 22 AWG stranded TC drain wire
- Datalene® insulation, black UV resistant PVC jacket (CPE jacket optional)
- Oil res II 300 V
- Conductor Nominal DCR conductor - 14.7Ω/M', 48.2Ω/km
- Conductor Nominal DCR shield - 1.4Ω/M', 4.6Ω/km
- Nominal OD - 0.420 inch / 10.67mm
| Standard Length (ft) |
1000 |
2000 |
| Standard Length (m) |
304.8 |
609.6 |
| Standard unit weight (lbs) |
93.0 |
184.0 |
| Standard unit weight (kgs) |
42.3 |
83.6 |
- 22 AWG stranded (7 x 30) tinned copper, twisted pairs, overall 100% Beldfoil® shield + 90% TC braid, 22 AWG stranded TC drain wire
- Datalene® insulation, black UV resistant PVC jacket (CPE jacket optional)
- Oil res II 300 V
- Conductor Nominal DCR conductor - 14.7Ω/M', 48.2Ω/km
- Conductor Nominal DCR shield - 1.1Ω/M', 3.6Ω/km
- Nominal OD - 0.420 inch / 10.67mm
| Standard Length (ft) |
1000 |
2000 |
| Standard Length (m) |
304.8 |
609.6 |
| Standard unit weight (lbs) |
107.0 |
218.0 |
| Standard unit weight (kgs) |
48.6 |
99.1 |