Click to send us a

|
|
 |
Belden Industrial Twin Cables
Belden industrial data solutions - industrial Ethernet coaxial
cables - blue hose cables. CSE supplies a range of the Belden coaxial cables. |
|
CSE holds supplies a wide range of Belden cables - Contact Corrina, our cable expert at
|
|
|
- 78 Ohm, 20AWG
- Stranded (7 x 28) .38"
- Tinned Copper
- Beldfoil® + 55% Tinned
copper braid shield (100% shield coverage)
|
|
|

Blue Hose - Shielded |
Conductor (stranding) diameter Nom. DCR - 20 AWG
(7 x 28) .038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
Nominal OD .238", 6.05mm
| Standard Length (ft) |
100 |
U-500 |
500 |
U-1000 |
1000 |
6000 |
10000 |
| Standard Length (m) |
30.5 |
U-152.4 |
152.4 |
U-304.8 |
304.8 |
1828.7 |
3048 |
| Standard unit weight (lbs) |
4.6 |
18.5 |
18.5 |
37.0 |
37.0 |
222.0 |
370.0 |
| Standard unit weight (kgs) |
2.1 |
8.4 |
8.4 |
16.8 |
16.8 |
100.9 |
168.2 |
- Polyethylene Insulation
- Blue low smoke
- Zero halogen jacket
- Steel wired armour
Conductor (stranding) diameter Nom. DCR - 20 AWG (7 x 28)
.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
Nominal OD - 0.250inch / 6.35mm under armour, 0.423inch /
10.75mm over armour
| Standard Length (ft) |
1640 |
3280 |
4920 |
| Standard Length (m) |
500 |
1000 |
1500 |
| Standard unit weight (lbs) |
248.9 |
537.4 |
925.1 |
| Standard unit weight (kgs) |
113.0 |
244.0 |
420.0 |
- Polyethylene Insulation
- Blue low smoke
- Zero halogen jacket
Conductor (stranding) diameter Nom. DCR - 20 AWG (7 x 28)
.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
Nominal OD - 0.250inch / 6.35mm
| Standard Length (ft) |
1000 |
1640 |
3280 |
| Standard Length (m) |
305 |
500 |
1000 |
| Standard unit weight (lbs) |
37.4 |
64.5 |
117.4 |
| Standard unit weight (kgs) |
17.0 |
29.3 |
53.3 |
- 78 Ohm
- 20AWG stranded (42 x 36) 0.038" Tinned copper
- Overall Beldfoil + 85% Tinned copper braid shield (100%
coverage)
- Polyethylene Insulation
- Blue sunlight resistant PVC jacket
- High flex blue hose UL AWM Style 2464 (300V 60oC)
Conductor (stranding) diameter Nom. DCR - 20 AWG (42 x 36)
0.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
Nominal OD - 0.243inch / 6.17mm
| Standard Length (ft) |
1000 |
5000 |
| Standard Length (m) |
304.8 |
1524.0 |
| Standard unit weight (lbs) |
42.0 |
205.0 |
| Standard unit weight (kgs) |
19.1 |
93.2 |
- 78 Ohm, 20 AWG stranded (7 x 28) 0.038" tinned copper
- Beldfoil + 55% tinned copper braid shield (100% shield coverage)
- Polyethylene insulation
- Blue sunlight resistant LDPE Jacket
- Flooded direct burial blue hose 300V 80oC
- Conductor (stranding) diameter Nom. DCR - 20 AWG (7 x 28)
0.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
- Nominal OD - 0.240 inch / 6.10mm
| Standard Length (ft) |
1000 |
5000 |
| Standard Length (m) |
304.8 |
1524.0 |
| Standard unit weight (lbs) |
33.0 |
155.0 |
| Standard unit weight (kgs) |
15.0 |
70.5 |
- 78 Ohm, 20 AWG stranded (7 x 28) tinned copper
- Overall Beldfoil + 55% tinned copper braid shield (100% coverage)
- Aluminium interlocked armour
- PE Inuslation
- Blue sunlight resistant PVC outer Jacket
- Aluminium armoured blue hose 300V 60oC
- Conductor (stranding) diameter Nom. DCR - 20 AWG (7 x 28)
0.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
- Nominal OD - Core 0.2238 inch / 6.05mm; Armour 0.563" /
14.30 mm
| Standard Length (ft) |
1000 |
6000 |
| Standard Length (m) |
304.8 |
1828.8 |
| Standard unit weight (lbs) |
122.0 |
924.0 |
| Standard unit weight (kgs) |
55.5 |
420.0 |
- 78 Ohm, 20 AWG stranded (7 x 28) 0.038" tinned copper
- Overall Beldfoil + 56% tinned copper braid shield (100%
coverage)
- Plenum
- FEP insulation
- Blue FEP jacket
- High temperature blue hose 300V 200oC
- Conductor (stranding) diameter Nom. DCR - 20 AWG (7 x 28)
0.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
- Nominal OD - 0.203inch / 5.16mm
| Standard Length (ft) |
1000 |
2500 |
| Standard Length (m) |
304.8 |
762.0 |
| Standard unit weight (lbs) |
36.0 |
90.0 |
| Standard unit weight (kgs) |
16.4 |
40.9 |
- 78 Ohm, 20 AWG stranded (7 x 28) tinned copper
- Overall Beldfoil + 55% tinned copper braid shield (100%)
coverage
- Steel interlocked armour
- Steel armoured blue hose 300V 60oC
- PE insulation
- Blue sunlight resistant PVC outer Jacket
- Conductor (stranding) diameter Nom. DCR - 20 AWG (7 x 28)
0.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
- Nominal OD - Core 0.238inch / 6.05mm; Armour 0.563" /
14.30mm
| Standard Length (ft) |
1000 |
6000 |
| Standard Length (m) |
304.8 |
1828.8 |
| Standard unit weight (lbs) |
222.0 |
100.0 |
| Standard unit weight (kgs) |
1488.0 |
676.4 |
- 78 Ohm, 20 AWG stranded (7 x 28) tinned copper
- Overall Beldfoil + 55% tinned copper braid shield (100%)
coverage
- Continuously corrugated AL armour
- PE insulation
- Blue sunlight resistant PVC outer Jacket
- Continuously armoured blue hose 300V 60oC
- Conductor (stranding) diameter Nom. DCR - 20 AWG (7 x 28)
0.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
- Nominal OD - Core 0.238inch / 6.05mm; Armour 0.500" /
12.70mm
| Standard Length (ft) |
6000 |
| Standard Length (m) |
1828.8 |
| Standard unit weight (lbs) |
864.0 |
| Standard unit weight (kgs) |
392.7 |
- 78 Ohm, 20 AWG stranded (7 x 28) tinned copper
- 93% tinned copper braid shield
- Polyethylene insulation
- Blue PVC Jacket
- UL AWM Style 2092 (300V 60oC)
- Conductor (stranding) diameter Nom. DCR - 20 AWG (7 x 28)
0.038", Tinned Copper 9.5 Ω/ M', 31.0
Ω /km
- Nominal OD - Core 0.244inch / 6.20mm
| Standard Length (ft) |
100 |
U-500 |
500 |
U-1000 |
1000 |
| Standard Length (m) |
30.5 |
U-152.4 |
152.4 |
U-304.8 |
304.8 |
| Standard unit weight (lbs) |
4.9 |
20.0 |
20.0 |
39.0 |
40.0 |
| Standard unit weight (kgs) |
2.2 |
9.1 |
9.1 |
17.7 |
18.2 |
|