Belden Interconnect Shielded Twisted Pair Cable
Belden industrial data solutions - CSE Supplies the genuine Belden Internconnect cable - shielded twisted pair cables.
- 22 AWG stranded (7 x 30)
- Tinned copper
- Twisted pairs
- Individually shielded with 100% Beldfoil
- 24 AWG Stranded TC drain wire
- Polypropylene insulation
- Chrome PVC jacket (Pairs cabled on common axis to reduce diameter)
- 300V RMS 60oC
- Conductor Nom. DCR - 15.0 Ω/ M', 49.2 Ω /km
- Shield Nom. DCR - 16.6 Ω/ M', 54.5 Ω /km
- Nominal core OD - 0.168", 4.27mm
| Standard Length (ft) |
100 |
U-500 |
500 |
U-1000 |
1000 |
1640 |
U-2000 |
2000 |
3280 |
5000 |
10000 |
| Standard Length (m) |
30.5 |
U152.4 |
152.4 |
U304.8 |
499.9 |
499.9 |
U-609.6 |
609.6 |
999.7 |
1524 |
3048 |
| Standard unit weight (lbs) |
2.3 |
10.5 |
10.0 |
20.0 |
20.0 |
32.8 |
40.0 |
40.0 |
65.6 |
95.0 |
200 |
| Standard unit weight (kgs) |
1.0 |
4.8 |
4.5 |
9.1 |
9.1 |
14.9 |
18.2 |
18.2 |
29.8 |
43.2 |
90.9 |
- 22 AWG stranded (7 x 30)
- Tinned copper
- Twisted pairs
- Individually shielded with 100% Beldfoil
- 24 AWG Stranded TC drain wire
- Plenum, FEP insulation
- Red FEP jacket (pairs cabled on common axis to reduce diameter)
- 300V RMS Non conduit
- Conductor Nom. DCR - 16.0 Ω/ M', 52.5 Ω /km
- Shield Nom. DCR - 16.6 Ω/ M', 54.5 Ω /km
- Nominal core OD - 0.148", 3.76mm
| Standard Length (ft) |
100 |
500 |
1000 |
| Standard Length (m) |
30.5 |
152.4 |
499.9 |
| Standard unit weight (lbs) |
3.4 |
11.0 |
21.0 |
| Standard unit weight (kgs) |
1.5 |
5.0 |
9.5 |
- 24 AWG stranded (7 x 32)
- Tinned copper
- Twisted pairs
- Individually shielded with 100% Beldfoil
- 24 AWG Stranded TC drain wire
- UL AWM Style 2493 (300V 60oC)
- Datalene ® Insulation
- Chrome PVC jacket
- Conductor Nom. DCR - 24.0 Ω/ M', 78.7 Ω /km
- Shield Nom. DCR - 18.0 Ω/ M', 59.1 Ω /km
- Nominal OD - 0.317", 8.05mm
| Standard Length (ft) |
100 |
500 |
1000 |
10000 |
| Standard Length (m) |
30.5 |
152.4 |
304.8 |
3048.0 |
| Standard unit weight (lbs) |
4.3 |
20.5 |
39.0 |
390.0 |
| Standard unit weight (kgs) |
2.0 |
9.3 |
17.7 |
177.8 |
- 22 AWG stranded (7 x 30)
- Tinned copper
- Twisted pairs
- Individually shielded with 100% Beldfoil
- 22 AWG Stranded TC drain wire
- UL AWM Style 2919 (30V 80oC)
- Polypropylene insulation
- Chrome PVC jacket
- Conductor Nom. DCR - 15.0 Ω/ M', 49.2 Ω /km
- Shield Nom. DCR - 10.6 Ω/ M', 34.8 Ω /km
- Nominal OD - 0.273", 6.93mm
| Standard Length (ft) |
100 |
250 |
U-500 |
500 |
U-1000 |
1000 |
1640 |
3280 |
5000 |
10000 |
| Standard Length (m) |
30.5 |
76.2 |
U-152.4 |
152.4 |
U-304.8 |
304.8 |
499.9 |
999.7 |
1524.0 |
3048.0 |
| Standard unit weight (lbs) |
5.3 |
11.3 |
21.0 |
21.0 |
41.0 |
42.0 |
67.2 |
137.8 |
210.0 |
450.0 |
| Standard unit weight (kgs) |
2.4 |
5.1 |
9.5 |
9.5 |
18.7 |
19.1 |
30.6 |
62.6 |
95.5 |
204.5 |
- 22 AWG stranded (7 x 30)
- Tinned copper
- Twisted pairs
- Individually shielded with 100% Beldfoil
- 22 AWG Stranded TC drain wire
- 300V 80oC
- Polypropylene insulation
- Black low smoke, zero halogen jacket, steel wire armour
- Conductor Nom. DCR - 15.0 Ω/ M', 49.2 Ω /km
- Shield Nom. DCR - 10.6 Ω/ M', 34.8 Ω /km
- Nominal OD - 0.273", 6.93mm
| Standard Length (ft) |
1640 |
3280 |
| Standard Length (m) |
500 |
1000 |
| Standard unit weight (lbs) |
290.1 |
711.9 |
| Standard unit weight (kgs) |
131.7 |
323.2 |
- 22 AWG stranded (7 x 30)
- Tinned copper
- Twisted pairs
- Individually shielded with 100% Beldfoil
- 22 AWG Stranded TC drain wire
- 300V 80oC
- Polypropylene insulation
- Chrome low smoke, zero halogen jacket
- Conductor Nom. DCR - 15.0 Ω/ M', 49.2 Ω /km
- Shield Nom. DCR - 10.6 Ω/ M', 34.8 Ω /km
- Nominal OD - 0.273", 6.93mm
| Standard Length (ft) |
1000 |
1640 |
3280 |
| Standard Length (m) |
305 |
500 |
1000 |
| Standard unit weight (lbs) |
50.7 |
78.4 |
151.3 |
| Standard unit weight (kgs) |
23.0 |
35.6 |
68.7 |