Moeller Industrial Miniature Circuit BreakersIndustrial Miniature Circuit Breakers

The comprehensive range of Xpole miniature circuit-breakers includes 10 and 15 kA switching capacity in single-pole and multi-pole versions. The range offers the following tripping characteristics:

  • Type B - for domestic / commercial installations without power surges eg filament lamps and wall sockets
  • Type C - for commercial / light industrial installations, with switching surges such as fluorescent lighting or small motors
  • Type D - for abnomrally high inrush currents e.g. motors with heavy starting duty
  • Type S - for the protection of control circuits with high inrush currents and transformers

In addition, the range includes components for residual current protection and modular installation devices for remote switching, timing and signalling.

Features and Benefits

  • Xpole range offers worldwide approvals and shipping classification
  • DIN rail clip mounting, and snap fitting accessories reduce installation time and simplify fitting and removal of components
  • Single design concept improves panel appearance
  • Busbar clamps and high capacity box terminals provide increased connection options
  Moeller Single Pole MCB Moeller Double Pole MCB Moeller Triple Pole MCB
Rated current In Single Pole Double Pole Triple Pole
A Part Number Part Number Part Number
15 kA, Type B
3-5 x In response current of short circuit trip
4 FAZ-B4/1-HS FAZ-B4/2-HS  
6 FAZ-B6/1 FAZ-B6/2 FAZ-B6/3
10 FAZ-B10/1 FAZ-B10/2 FAZ-B10/3
12 FAZ-B12/1 FAZ-B12/2 FAZ-B12/3
16 FAZ-B16/1 FAZ-B16/2 FAZ-B16/3
20 FAZ-B20/1 FAZ-B20/2 FAZ-B20/3
25 FAZ-B25/1 FAZ-B25/2 FAZ-B25/3
32 FAZ-B32/1 FAZ-B32/2 FAZ-B32/3
40 FAZ-B40/1 FAZ-B40/2 FAZ-B40/3
50 FAZ-B50/1 FAZ-B50/2 FAZ-B50/3
63 FAZ-B63/1 FAZ-B63/2 FAZ-B63/3
15kA, Type C
5 - 10 x In response current of short circuit trip
0.5 FAZ-C0,5/1 FAZ-C0,5/2 FAZ-C0,5/3
1 FAZ-C1/1 FAZ-C1/2 FAZ-C1/3
2 FAZ-C1/1 FAZ-C1/2 FAZ-C1/3
4 FAZ-C4/1 FAZ-C4/2 FAZ-C4/3
6 FAZ-C6/1 FAZ-C6/2 FAZ-C6/3
10 FAZ-C10/1 FAZ-C10/2 FAZ-C10/3
16 FAZ-C16/1 FAZ-C16/2 FAZ-C16/3
20 FAZ-C20/1 FAZ-C20/2 FAZ-C20/3
25 FAZ-C25/1 FAZ-C25/2 FAZ-C25/3
32 FAZ-C32/1 FAZ-C32/2 FAZ-C32/3
40 FAZ-C40/1 FAZ-C40/2 FAZ-C40/3
50 FAZ-C50/1 FAZ-C50/2 FAZ-C50/3
63 FAZ-C63/1 FAZ-C63/2 FAZ-C63/3
15kA, Type D
5 - 20 x In response current of short circuit trip
0.5 FAZ-D0.5/1 FAZ-D0.5/2 FAZ-D0.5/3
1 FAZ-D1/1 FAZ-D1/2 FAZ-D1/2
2 FAZ-D2/1 FAZ-D2/2 FAZ-D2/3
4 FAZ-D4/1 FAZ-D4/2 FAZ-D4/3
6 FAZ-D6/1 FAZ-D6/2 FAZ-D6/3
10 FAZ-D10/1 FAZ-D10/2 FAZ-D10/3
16 FAZ-D16/1 FAZ-D16/2 FAZ-D16/3
20 FAZ-D20/1 FAZ-D20/2 FAZ-D20/3
25 FAZ-D25/1 FAZ-D25/2 FAZ-D25/3
32 FAZ-D32/1 FAZ-D32/2 FAZ-D32/3
40 FAZ-D40/1 FAZ-D40/2 FAZ-D40/3
50 FAZ-D50/1 FAZ-D50/2 FAZ-D50/3
63 FAZ-D63/1 FAZ-D63/2 FAZ-D63/3
15kA, Type K
8 - 12 x In response current of short circuit trip
0.5 FAZ-K0.5/1 FAZ-K0.5/2 FAZ-K0.5/3
1 FAZ-K1/1 FAZ-K1/2 FAZ-K1/3
2 FAZ-K2/1 FAZ-K2/2 FAZ-K2/3
4 FAZ-K4/1 FAZ-K4/2 FAZ-K4/3
6 FAZ-K6/1 FAZ-K6/2 FAZ-K6/3
10 FAZ-K10/1 FAZ-K10/2 FAZ-K10/3
16 FAZ-K16/1 FAZ-K16/2 FAZ-K16/3
20 FAZ-K20/1 FAZ-K20/2 FAZ-K20/3
25 FAZ-K25/1 FAZ-K25/2 FAZ-K25/3
32 FAZ-K32/1 FAZ-K32/2 FAZ-K32/3
40 FAZ-K40/1 FAZ-K40/2 FAZ-K40/3
50 FAZ-K50/1 FAZ-K50/2 FAZ-K50/3
63 FAZ-K63/1 FAZ-K63/2 FAZ-K63/3
10kA, Type S
13 - 17 x In response current of short circuit trip
1 FAZ-S1/1 FAZ-S1/2  
2 FAZ-S2/1 FAZ-S2/2  
3 FAZ-S3/1 FAZ-S3/2  
4 FAZ-S4/1 FAZ-S4/2  
6 FAZ-S6/1 FAZ-S6/2  
10 FAZ-S10/1 FAZ-S10/2  
16 FAZ-S16/1 FAZ-S16/2  
20 FAZ-S20/1 FAZ-S20/2  
25 FAZ-S25/1 FAZ-S25/2  
32 FAZ-S32/1 FAZ-S32/2  
40 FAZ-S40/1 FAZ-S40/2  
10kA, Type B
3 - 5 x In response current of short circuit trip
2 PLSM-B2 PLSM-B2/2 PLSM-B2/3
4 PLSM-B4 PLSM-B4/2 PLSM-B4/3
6 PLSM-B6 PLSM-B6/2 PLSM-B6/3
10 PLSM-B10 PLSM-B10/2 PLSM-B10/3
13 PLSM-B13 PLSM-B13/2 PLSM-B13/3
16 PLSM-B16 PLSM-B16/2 PLSM-B16/3
20 PLSM-B20 PLSM-B20/2 PLSM-B20/3
25 PLSM-B25 PLSM-B25/2 PLSM-B25/3
32 PLSM-B32 PLSM-B32/2 PLSM-B32/3
40 PLSM-B40 PLSM-B40/2 PLSM-B40/3
50 PLSM-B50 PLSM-B50/2 PLSM-B50/3
63 PLSM-B63 PLSM-B63/2 PLSM-B63/3
10kA, Type C
5 - 10 x In response current of short circuit trip
2 PLSM-C2 PLSM-C2/2 PLSM-C2/3
4 PLSM-C4 PLSM-C4/2 PLSM-C4/3
6 PLSM-C6 PLSM-C6/2 PLSM-C6/3
10 PLSM-C10 PLSM-C10/2 PLSM-C10/3
13 PLSM-C13 PLSM-C13/2 PLSM-C13/3
16 PLSM-C16 PLSM-C16/2 PLSM-C16/3
20 PLSM-C20 PLSM-C20/2 PLSM-C20/3
25 PLSM-C25 PLSM-C25/2 PLSM-C25/3
32 PLSM-C32 PLSM-C32/2 PLSM-C32/3
40 PLSM-C40 PLSM-C40/2 PLSM-C40/3
50 PLSM-C50 PLSM-C50/2 PLSM-C50/3
63 PLSM-C63 PLSM-C63/2 PLSM-C63/3
10kA, Type D
10 - 20 x In response current of short circuit trip
2 PLSM-D2 PLSM-D2/2 PLSM-D2/3
4 PLSM-D4 PLSM-D4/2 PLSM-D4/3
6 PLSM-D6 PLSM-D6/2 PLSM-D6/3
10 PLSM-D10 PLSM-D10/2 PLSM-D10/3
13 PLSM-D13 PLSM-D13/2 PLSM-D13/3
16 PLSM-D16 PLSM-D16/2 PLSM-D16/3
20 PLSM-D20 PLSM-D20/2 PLSM-D20/3
25 PLSM-D25 PLSM-D25/2 PLSM-D25/3
32 PLSM-D32 PLSM-D32/2 PLSM-D32/3
40 PLSM-D40 PLSM-D40/2 PLSM-D40/3
50 PLSM-D50 PLSM-D50/2 PLSM-D50/3
63 PLSM-D63 PLSM-D63/2 PLSM-D63/3

PLSM circuit breakers have colour coded toggle switches, as follow:

PLSM Colour Coded Toggle Switches

Click for Moeller Installation devices (RCD / RCBO / Modular contactors and time switches)

MCB System Overview