PS S 03 – 25 for normal starts
Motor rating 230V Pe kW |
400V Pe kW |
Motor rating 230V Pe kW |
400V Pe kW |
Current le A |
Order Code |
– | 1.1 | – | – | 3 | PS S 03-400B |
– | 5.5 | – | – | 12 | PS S 12-400B |
– | 11.0 | – | – | 25 | PS S 25-400B |
PS S 18 / 30 … 142 / 245 For Normal Starts
Inline Motor Rating 230V Pe kW |
400V Pe kW | 500V Pek W | Current le A |
Inside Delta Motor Rating 230V Pe kW |
400V Pe kW |
500V Pe kW |
Current le A |
Order Code |
4 | 7.5 | 11 | 18 | 7.5 | 15 | 18.5 | 30 | PS S 18/30-500 |
7.5 | 15 | 18.5 | 30 | 12.5 | 25 | 30 | 52 | PS S 30/52-500 |
9 | 18.5 | 22 | 37 | 15 | 30 | 37 | 64 | PS S 37/64-500 |
11 | 22 | 25 | 44 | 22 | 37 | 45 | 76 | PS S 44/76-500 |
12.5 | 25 | 30 | 50 | 25 | 45 | 55 | 85 | PS S 50/85-500 |
15 | 30 | 37 | 60 | 30 | 55 | 75 | 105 | PS S 60/105-500 |
18.5 | 37 | 45 | 72 | 37 | 59 | 80 | 124 | PS S 72/124-500 |
22 | 45 | 55 | 85 | 40 | 75 | 90 | 147 | PS S 85/147-500 |
30 | 55 | 75 | 105 | 55 | 90 | 110 | 181 | PS S 105/181-500 |
37 | 75 | 90 | 142 | 75 | 132 | 160 | 245 | PS S 142/245-500 |
45 | 90 | 110 | 175 | 90 | 160 | 200 | 300 | PS S 175/300-500 |
75 | 132 | 160 | 250 | 132 | 220 | 295 | 430 | PS S 250/430-500 |
90 | 160 | 200 | 300 | 160 | 257 | 355 | 515 | PS S 300/515-500 |
For heavy duty starting and 690V applications please call.
Soft Starters Accessories
Current Transformer for current limit function
To be connected to terminals 11 and 12 on the soft starter. The setting range (1.5 – 4) corresponds to a multiple of the transformer ratio. Technical data below shows transformer ratio and number of turns for the primary winding.
Current Transformer | For Softstarter | Weight kg | Order Code |
60/1 – 2 turns | PS S 18/30 | 0.3 | PS CT-60 |
40/1 – 1 turn | PS S 30/52 | 0.3 | PS CT-40 |
50/1 – 1 turn | PS S 37 / 64 | 0.3 | PS CT-50 |
60/1 – 1 turn | PS S 44/76 | 0.3 | PS CT-60 |
75/1 – 1 turn | PS S 50/85 | 0.3 | PS CT-75 |
75/1 – 1 turn | PS S 60/105 | 0.3 | PS CT-75 |
100/1 – 1 turn | PS S 72/124 | 0.25 | PS CT-100 |
125/1 – 1 turn | PS S 85/147 | 0.25 | PS CT-125 |
150/1 – 1 turn | PS S 105/181 | 0.25 | PS CT-150 |
200/1 – 1 turn | PS S 142/245 | 0.25 | PS CT-200 |
250/1 – 1 turn | PS S 175/300 | 0.25 | PS CT-250 |
400/1 – 1 turn | PS S 250/430 | 0.25 | PS CT-400 |
400/1 – 1 turn | PS S 300/515 | 0.25 | PS CT-400 |
Cable Connectors for Cu Cables (set of 3)
Wire range | Tightening torque max. Nm | For softstarter | Weight kg | Order Code |
6-185 mm2 | 16 | PS S 85/147 … 142/245 | 0.2 | 1SDA023354R1 |
2 x (50-1210) mm2 | 16 | PS S 85/147 … 142/245 | 0.3 | LZ 185-2C/120 |
16-240 mm2 | 25 | PS S 175/300 … 300/515 | 0.4 | 1SDA023368R1 |
Cable Connectors for Al and Cu Cables (set of 3)
Wire range | Tightening torque | For softstarter | Weight kg | Order Code |
35-95 mm2 | 13.35 | PS S 85/147 … 142 /245 | 0.2 | 1SDA023354R1 |
25 -150 mm2 | 31 | PS S 85/147 .. 142 /245 | 0.1 | 1SDA023357R1 |
120-240 mm2 | 43 | PS S 175/300 … 300/515 | 0.1 | 1SDA023379R1 |
Terminal Shrouds (set of 2)
For softstarter | Weight kg | Order Code | |
For cable connectors | PS S 85/147 … 142/245 | 0.1 | LT185-AC |
For compression lugs | PS S 85/147 … 142/245 | 0.1 | LT 185-AL |
For cable connectors | PS S 175/300 … 300/515 | 0.2 | LT 300-AC |
For compression lugs | PS S 175/300 … 300/515 | 0.2 | LT300-AL |
Terminal Nut Washer (set of 2)
For softstarter | Weight kg | Order Code |
PS S 85/147 … 142/245 | 0.2 | LE 185 |
PS S 175/300 … 300/515 | 0.3 | LE 300 |
Terminal Shrouds (set of 2)
For softstarter | Weight kg | Order Code |
PS S 18/30 … 44/76 | 0.1 | PS LW-44 |
PS S 50/85 … 72/124 | 0.15 | PS LW-72 |
PS S 85/147 … 142/245 | 0.25 | LW 185 |
PS S 175/300 … 300/515 | 0.4 | LW-300 |