Medium Voltage Power Cable 3.3kV PVC SWA

BS5467 & IEC60502-1 Cu/XLPE/PVC/SWA/PVC 1.9/3.3kV

Cu/XLPE/PVC/SWA/PVC mains power cable may be used for fixed installation indoors and outdoors directly in the ground. The cable is XLPE insulated, PVC bedded, Steel Wire Armoured and PVC sheathed with annealed copper conductors complying with BS6360 Class 2. 1900/3300 volts complying to BS5467 and IEC 60502-1, flame retardant to IEC 60332-1.

Construction Characteristics

Conductor material: Copper - IEC60228
Conductor shape: 16mm² & 25mm² - Circular

35mm² - Sector-shaped or Circular

50mm² up to 400mm² - Sector-shaped
Conductor flexibility: Stranded class 2
Insulation: XLPE (Cross-linked Polyethylene) - IEC60502
Inner sheath: PVC - IEC60502
Armour type: Galvanized steel wires
Outer sheath: PVC - IEC60502
Colour: Black
Lead free: Yes

Electrical Characteristics

Rated Voltage Uo/U (Um): 1900/3300 Volts - BS5467 IEC60502-1

Usage Characteristics

Minimum installation temperature: 0°C
Maximum installation temperature: +60°C
Installation type: Outdoor - Direct burial
Minimum operating temperature: -15°C
Maximum operating temperature: 90°C
Short-circuit max. conductor temperature: 250°C
Flame retardant: BS EN 60332 / IEC 60332-1
Bending radius: 8 x Overall diameter

3 Core: Brown, Black & Grey

Part Number Cross Section Stranding Approx Weight Approx Overall Diameter Gland Size Single Cleat Nom. Max. DC-resist conductor 20⁰ C Current Rating Direct in ground
(mm²) (mm) KG/KM (mm) (mm)
(Ohm/km) (Amp)
3.3SWAPVC3X16 3 x 16 7/1.70 1690 29.2 32 1.2 1.15 75
3.3SWAPVC3X25 3 x 25 7/2.14 2170 32.3 32 1.4 0.727 96
3.3SWAPVC3X35 3 x 35 7/2.52 2550 35.0 40 1.4 0.524 115
3.3SWAPVC3X50 3 x 50 19/1.78 3130 34.8 40 1.4 0.387 135
3.3SWAPVC3X70 3 x 70 19/2.14 3910 38.0 40 1.6 0.268 167
3.3SWAPVC3X95 3 x 95 19/2.52 4845 41.4 50s 1.8 0.193 197
3.3SWAPVC3X120 3 x 120 37/2.03 6185 45.64 50s 1.8 0.153 223
3.3SWAPVC3X150 3 x 150 37/2.25 7195 48.4 50 2.0 0.124 251
3.3SWAPVC3X185 3 x 185 37/2.52 8455 51.75 50 TC9 0.0991 281
3.3SWAPVC3X240 3 x 240 61/2.25 10485 56.7 63s TC9 0.0754 324
3.3SWAPVC3X300 3 x 300 61/2.52 12485 60.95 63 TC10 0.0601 365
3.3SWAPVC3X400 3 x 400 61/2.85 15370 66.2 75s TC11 0.0470 -

Conditions of installation:

Ambient air temperature: 30°C
Ground temperature: 20°C
Maximum conductor temperature: 90°C

Where a conductor operates at a temperature exceeding 70°C it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature (see Regulation 512.1.2).

Where cables in the above table are connected to the equipment or accessories designed to operate at a temperature not exceeding 70 °C, the current rating given in the equivalent table for 70 °C thermoplastic insulated cables (Table 4D4A) must be used (also see Regulation 523.1).


Suitable gland types:

CW CIEL – Brass: Internal & External