Belden 1885 ENH Cat 7 Cable

Belden 1885 ENH Cat 7 Cable

The Belden 1885 ENH Category 7 SFTP FRNC data networking cable is used for horizontal and building backbone cable. It supports all existing and proposed Cat 7 applications such as 100 Base TX, 100 Base VG AnyLan, 155 ATM and 1000 Base-T (Gigabit Ethernet), FDDI. The Cat 7 cable also features excellent stability of Impedance and NEXT performance.

Cable Construction

Number of Pairs: 4 individually shielded twisted pairs
Conductor Material: Solid bare copper
Conductor Diameter: AWG 23 (0.57mm)
Conductor Insulation Material: Foam skin Polyolefine
Diameter over insulation: 1.45mm ± 0.05mm
Shield : Tinned Copper Braid
Shield Coverage: 40% coverage
Ripcord: Polyester
Jacket Material: FRNC
Outer Diameter: 8.0mm ± 0.3mm
Standards: FCD ISO/IEC 11801 (October 2001)
prEN 50288-3-1
ISO/IEC 11801 2nd edition
EN 50173 2nd edition
Cable Sheath Colour: Grey / RAL 7032 / G900 (Belden Code)
Cable Marking: BELDEN 1885ENH ISTP “CAT7” 4PR AWG23 LSNH ISO/IEC 11801 EN50173
(DIN 44312-5) VERIFIED 100 OHM

Electrical Properties (at 20°C)

Nominal mutual capacitance at 1 kHz 48 nF/km
Maximum conductor DCR 75 Ohm/km
NVP - Nominal Velocity of Propagation 0.75 c
SKEW – Propagation delay difference (100 MHz) typical 15 ns/100m
Impedance 1-100 MHz 100 ± 15 Ohm
Impedance 100-250 MHz 100 ± 18 Ohm
Impedance 250-600 MHz 100 ± 25 Ohm

Attenuation

Frequency (MHz) 1 4 10 16 20 31.2 62.5 100 155 200 300 600
Spec. (Max.)* (dB/100m) 2.0 3.7 5.9 7.4 8.5 10.4 14.9 19.0 24.0 27.5 34.2 50.1
Typical 1.9 3.5 5.4 6.9 7.6 9.6 13.6 17.4 21.7 24.7 30.5 44.6

NEXT (Near End Crosstalk)

Frequency (MHz) 1 4 10 16 20 31.2 62.5 100 155 200 300 600
Spec. (Min.)* dB/100m) 80 80 80 80 80 80 75 72 70 68 65 61
Typical 100 100 100 100 100 100 100 95 95 95 90 90

Power sum NEXT

Frequency (MHz) 1 4 10 16 20 31.2 62.5 100 155 200 300 600
Spec. (Min.)* dB/100m) 77 77 77 77 77 77 72 69 67 65 62 58
Typical 98 98 98 98 98 98 98 93 93 93 88 88

Power sum ELFEXT

Frequency (MHz) 1 4 10 16 20 31.2 62.5 100 155 200 300 600
Spec. (Min.)* dB/100m) 75 75 71 67 65 61 55 51 47 45 41 35
Typical 95 95 95 90 87 84 80 76 72 70 65 50

Power sum ACR

Frequency (MHz) 1 4 10 16 20 31.2 62.5 100 155 200 300 600
Spec. (Min.)* dB/100m) 73 73 71.1 69.6 68.5 66.6 57.1 50 43 37.5 27.8 7.9
Typical 96 94 92 91 90 88 84 75 71 68 57 43

Mechanical Properties

Temperature Range Operation: -20°C to +60°C
Temperature Range Installation: +0°C to + 50°C
Minimum bending radius operation: 30 mm
Minimum bending radius installation: 60 mm
Maximum pulling tension: 90 N
Flame Retardancy: IEC 332-1
Energy of Flame: 500 kJ/m
Weight (approx): 60 kg/km
Maximum operating voltage: 48 V rms
Maximum continuous current per conductor (25°C) 1.4 A

Ordering Information

Order Code Delivery Length Weight Note
D9000 G900 D05 500m 30.0kg Non returnable reel