Belden 8761 Single Pair Cable

Belden 8761 Cable

The Belden 8761 Paired single pair cable is a 22 AWG stranded (7 x 30) tinned copper conductor, polyethylene insulation, twisted pair with Beldfoil® shield and PVC jacket.

Cable Construction

Number of Pairs: 1
Total Number of Conductors: 2
AWG: 22
Stranding: 7 x 30
Conductor Material: Tinned Copper (TC)
Insulation Material: Polyethylene (PE)
Nominal Insulation Wall Thickness: 0.016"
Lay Length: 1.5"
Twists / ft: 8
Pair Colour Code: 1: Black & Clear
Outer Shield: 100% Beldfoil (r) Alumium Foil - Polyester Tape
Outer Shield Drain Wire AWG: 22
Outer Shield Drain Wire Stranding: Stranded
Outer Shield Drain Wire Conductor Material: Tinned Copper (TC)
Overall Nominal Diameter: 0.175"

Mechanical Properties

Operating Temperature Range: -20°C To +60°C
UL Temperature Rating: 60°C (UL AWM Style 2092)
Bulk Cable Weight: 16 lbs/1000 ft.
Max. Recommended Pulling Tension: 27 lbs
Minimum Bend Radius (Install) 1.75"
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
AWM Specification: UL Style 2092 (300 V 60°C)
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date: 01-01-2004
UL Flame Test: UL1685 UL Loading
Plenum: No
Plenum Number: 88761, 87761, 82761

Electrical Properties

Nominal Characteristic Impedance: 64 Ohms
Nominal Inductance: 0.2 μH/ft
Nominal Capacitance Conductor to Conductor @ 1 KHz: 24 pF/ft
Nominal Capacitance Conductor to Other Conductor & Shield @ 1 KHz 47 pF/ft
Nominal Conductor DC Resistance @ 20°C 16 Ohms/1000 f
Maximum Operating Voltage - UL 300 V RMS (UL AWM Style 2092)
Maximum Recommended Current: 2.9 Amps per conductor @ 25°C

Cable Ordering

Cable Code Description Cable Length (ft) Shipping Weight (lbs) Sheath Colour
8761 0601000 2 #22 PE FS PVC 1000 18 Chrome
8761 06010000 2 #22 PE FS PVC 10000 170 Chrome
8761 0602000 2 #22 PE FS PVC 2000 36 Chrome
8761 060500 2 #22 PE FS PVC 500 9 Chrome
8761 0605000 2 #22 PE FS PVC 5000 90 Chrome
8761 060U1000 2 #22 PE FS PVC U1000 17 Chrome
8761 060U500 2 #22 PE FS PVC U500 9 Chrome

Y = final put-up length may vary -10% to +20% from length shown. May contain 2 pieces. Minimum length of any one piece is 1500'.