Belden DeviceBus ® for ODVA DeviceNet™

Belden Industrial Data Solutions ®- Industrial Data - DeviceBus ® for ODVA DeviceNetTM

CSE holds supplies a wide range of Belden cables - Contact our team for more information.

Belden 3084A Devicebus (r) Thin Cable

Belden 3084A

  • 300V Class 2 Thin
  • 22 and 24 AWG Stranded Tinned Copper
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain Wire
  • PVC Insulation (Power)
  • FPE Insulation (data)
  • Lt Gray sunlight / oil resistant PVC jacket
  • Thin 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
  • Nominal OD - 0.28", 7.11mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 26.0 49.0 100.0
Standard unit weight (kgs) 11.8 22.3 45.5

Belden 3082A Deveicebus (r) Thick CableBelden 3082A

  • 300V Class 2 thick
  • 15 and 18 AWG stranded tinned copper
  • 100% individually foil shielded + overall 65% TC braid
  • Drain Wire
  • PVC Insulation (power)
  • FPE insulation (data)
  • Lt grey sunlight / oil resistant PVC jacket
  • Thick 75oC
  • Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (19 x 28) 3.6 Ω / M', 11.8 Ω / km, 18 AWG TC (19 x 30) 6.9 Ω / M', 22.6 Ω / km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.9 Ω /km
  • Nominal core OD - 0.460", 11.68mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 64.0 128.0 260.0
Standard unit weight (kgs) 29.1 58.2 118.2

Belden 3082F

  • 300V Class 2 thick
  • 15 and 18 AWG stranded tinned copper
  • 100% individually foil shielded + overall 65% TC braid
  • Drain Wire
  • PVC Insulation (power)
  • FPE insulation (data)
  • Lt grey sunlight / oil resistant PVC jacket
  • Thick 75oC
  • Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (65 x 33) 3.6 Ω / M', 11.8 Ω / km, 18 AWG TC (65 x 36) 6.9 Ω / M', 22.6 Ω / km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.9 Ω /km
  • Nominal OD - 0.460", 11.68mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 72.0 140.0 284.0
Standard unit weight (kgs) 32.7 63.6 129.1

Belden 3082K

  • Flat, 16 AWG stranded (19 x 29) tinned copper
  • Unshielded
  • PVC insulation (power)
  • FPE insulation (data)
  • Lt. grey sunlight-resistant PVC jacket
  • Class 2 300V 75oC
  • Conductor (stranding) Diameter Nom. DCR - 16 AWG TC (19 x 29) 4.9 Ω / M', 16.1 Ω / km
  • Shielding materials Nom. DCR - unshielded
  • Nominal OD - 0.760 x 0.210", 10.92 x 5.33mm
Standard Length (ft) 246 656 1378
Standard Length (m) 75.0 200.0 420.0
Standard unit weight (lbs) 30.8 78.7 165.4
Standard unit weight (kgs) 14.0 35.8 75.2

Belden 3082KP

  • PVC insulation
  • Black sunlight-resistant PVC jacket
  • Conductor (stranding) Diameter Nom. DCR - 16 AWG TC (19 x 29) 4.9 Ω / M', 16.1 Ω / km
  • Shielding materials Nom. DCR - unshielded
  • Nominal OD - 0.760 x 0.210", 10.92 x 5.33mm
Standard Length (ft) 246 656 1378
Standard Length (m) 75.0 200.0 420.0
Standard unit weight (lbs) 32.0 81.3 170.9
Standard unit weight (kgs) 14.5 37.0 77.7

Belden 3083A

  • PVC Insulation (power)
  • FPE insulation (data)
  • Yellow CPE jacket
  • Thick 80oC
  • Conductor (stranding) Diameter Nom. DCR - 15 AWG TC (19 x 28) 3.6 Ω / M', 11.8 Ω / km; 18 AWG TC (19 x 30) 6.9 Ω / M', 11.8 Ω / km
  • Shielding materials Nom. DCR - unshielded
  • Nominal OD - 0.475", 12.07mm
Standard Length (ft) 1000 2000
Standard Length (m) 304.8 609.6
Standard unit weight (lbs) 133.0 270.0
Standard unit weight (kgs) 60.5 122.7

Belden 3084F

  • 300V Class 2 Thin
  • 22 and 24 AWG Stranded Tinned Copper
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain Wire
  • PVC Insulation (Power)
  • FPE Insulation (data)
  • Lt Gray sunlight / oil resistant PVC jacket
  • High flex Thin 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
  • Nominal OD - 0.275", 6.99mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 23.5 45.0 90.0
Standard unit weight (kgs) 10.7 20.5 40.9

Belden 3085A

  • 300V Class 2 Thin
  • 22 and 24 AWG Stranded Tinned Copper
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain Wire
  • PVC Insulation (power), FPE insulation (Data)
  • Yellow CPE jacket
  • Thin 80oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 22 AWG TC (154 x 44) 17.5 Ω/ M', 57.4 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 24 AWG TC (105 x 44) 28.0 Ω/ M', 91.9 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
  • Nominal OD - 0.280", 7.11mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 25.0 47.0 96.0
Standard unit weight (kgs) 11.4 21.4 43.6

Belden 7895A

  • 300V Class 2 ODVA Cable III
  • 20 and 18 AWG stranded TC
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain Wire
  • PVC Insulation (power), FPE insulation (Data)
  • Lt. grey sunlight / oil resistant PVC jacket
  • Mid 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 20 AWG TC (19 x 32) 10.9 Ω/ M', 35.8 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 3.2 Ω/ M', 10.5 Ω /km
  • Nominal OD - 0.378", 9.60mm
Standard Length (ft) 500 1000
Standard Length (m) 152.4 304.8
Standard unit weight (lbs) 42.0 83.0
Standard unit weight (kgs) 19.1 37.7

Belden 7896A

  • 600V Class 1 ODVA Cable V
  • 16 and 18 AWG Stranded tinned copper
  • 100% individually foil shielded + overall 65% TC Braid
  • PVC / nylon insulation (power)
  • F-R polypropylene insulation (data)
  • Open wiring 600V 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 16 AWG TC (19 x 29) 4.9 Ω/ M', 16.1 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.7 Ω /km
  • Nominal OD - 0.502", 12.75mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 70.0 136.0 276.0
Standard unit weight (kgs) 31.8 64.8 125.5

Belden 7897A

  • 600V Class 1 Thick
  • 15 and 18 AWG Stranded tinned copper
  • 100% individually foil shielded + overall 65% TC Braid
  • Drain wire
  • PVC / Nylon insulation (power); FEP Insulation (data)
  • Lt. grey sunlight / oil resistant PVC jacket
  • High velocity thick 600V 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 15 AWG TC (19 x 28) 3.6 Ω/ M', 11.8 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
  • Shielding materials Nom. DCR - 100% individual foil + overall 65% TC braid 1.8 Ω/ M', 5.7 Ω /km
  • Nominal OD - 0.440", 11.18mm
Standard Length (ft) 500 1000 2000
Standard Length (m) 152.4 304.8 609.6
Standard unit weight (lbs) 63.5 124.0 250.0
Standard unit weight (kgs) 28.9 56.4 113.6

Belden 7900A

  • 600V Class 1 ODVA Cable IV
  • 16 and 18 AWG Stranded tinned copper
  • Unshielded
  • PVC / Nylon insulation (power); FEP Insulation (data)
  • Lt. grey sunlight / oil resistant PVC jacket
  • High velocity thick 600V 75oC
  • Conductor (stranding) Diameter Nom. DCR - (2) 16 AWG TC (19 x 29) 4.9 Ω/ M', 16.1 Ω /km
  • Conductor (stranding) Diameter Nom. DCR - (2) 18 AWG TC (19 x 30) 6.9 Ω/ M', 22.6 Ω /km
  • Shielding materials Nom. DCR - Unshielded
  • Nominal OD - 0.430", 10.92mm
Standard Length (ft) 500 1000
Standard Length (m) 152.4 304.8
Standard unit weight (lbs) 45.0 92.0
Standard unit weight (kgs) 20.5 41.8

Want Monthly Offers, Promotions & News?

Sign up now to be the first to know about special offers, product news and industry information.